Service Difficulty Reports · N347FR
N347FR · 2019 AIRBUS A320-251N · Serial 8811
Service Difficulty Reports filed for N347FR, with the text of each report as the FAA holds it.
8 SDRs
POWER SUPPLY
- Difficulty date
- Submitted
- JASC
- 3350 · Lights
- Condition
- NO TEST
- Location
- ZONE 200
- Part number
- 321431
- Control number
- F3LA202508260287
AIRCRAFT WAS UNDERGOING HEAVY SERVICE CHECK DURING RON MAINTENANCE, ITEM #3 BATT/EPSU (11WL) EMER L FAULT. R&R EPSU BATTERY 11WL REF AMM 33-51-38-400-001-A/AMM 33-51-38-400-001 TEST OK.
CLAMP
- Difficulty date
- Submitted
- JASC
- 3610 · Pneumatic
- Condition
- LOOSE
- Location
- ZONE 400
- Control number
- F3LA202503070197
DISCREPANCY: ENG 1 FIRE ECAM AFTER LANDING. ENGINE 1 BOTTLE DISCHARGED. UPON INSPECTION OF THE #1 ENG, FOUND PYLON BLEED DUCT CLAMPS LOOSE. TORQUED PYLON DUCT CLAMPS IAW AMM 36-11-49-400-330-A. NO EVIDENCE OF A FIRE.
BATTERY
- Difficulty date
- Submitted
- JASC
- 3350 · Lights
- Condition
- FAILED
- Location
- ZONE 200
- Part number
- 32146210
- Control number
- F3LA2024092300142
REFERENCE LTPR NR 5001334222-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INCOMING CHECKS FOUND EPSU BATTERIES 10 WL INPO REPLACEMENT REQUIRED IAW AMM 33-51-38-000-002-A REV. 99. REPLACED EPSU BATTERY AND POWER SUPPLY 10WL IAW AMM 33-51-38-400-002-A REV. 99.
BATTERY
- Difficulty date
- Submitted
- JASC
- 3350 · Lights
- Condition
- FAILED
- Location
- ZONE 200
- Part number
- 32146210
- Control number
- F3LA2024092300141
REFERENCE LTPR NR 5001334233-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INCOMING CHECKS FOUND EPSU BATTERIES 11 WL INPO REPLACEMENT REQUIRED IAW AMM 33-51-38-000-002-A REV/99. REPLACED EPSU BATTERY AND POWER SUPPLY 11WL IAW AMM 33-51-38-400-002-A REV. 99.
BATTERY
- Difficulty date
- Submitted
- JASC
- 3350 · Lights
- Condition
- FAILED
- Location
- ZONE 200
- Part number
- 321431
- Control number
- F3LA2024092300143
REFERENCE LTPR NR 5001334236-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INCOMING CHECKS FOUND EPSU BATTERY 13 WL INOP. REPLACEMENT REQUIRED IAW AMM 33-51-38-000-002-A REV.99. REPLACED EPSU BATTERY 13WL IAW AMM 33-51-38-400-002 REV. 99.
DOOR SEAL
- Difficulty date
- Submitted
- JASC
- 5310 · Fuselage
- Condition
- CORRODED
- Location
- ZONE 200
- Part number
- D5348004320600
- Control number
- F3LA2024091800132
REFERENCE NR#5001334171-0010. AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. RH AFT DOOR SILL BEAM NUT PLATE HOLE AT FR68 IS CORRODED. REPAIR REQUIRED AFTER EVALUATION AS PER A320 NEO SRM 53-41-14-283-002 REV.41. REPAIRED BY INSTALLATION OF REPAIR ANGLE AND FILLER ON RH AFT PAX DOOR SILL AT FR68 AS PER A320 NEO SRM 53-41-14-300-001 PRINCIPLE 5 REV.41.
TUBE
- Difficulty date
- Submitted
- JASC
- 2910 · Hydraulic Power
- Condition
- DAMAGED
- Part number
- D2902083800000
- Control number
- F3LA2022040800024
DISCREPANCY: LP188829-2, HYD G RSVR LO LVL. CORRECTIVE ACTION: SERVICED HYD G RSVR IAW AMM 12-12-29-611-001-A, ADDITIONAL CORRECTIVE ACTION FROM LP188830-2: #1 ENG HYD LEAK FOUND. CORRECTIVE ACTION: R/R PRESS ASSY IAW AMM 20-23-11-911-001-A./END/
CONNECTOR
- Difficulty date
- Submitted
- JASC
- 3397 · Lights
- Condition
- LOOSE
- Location
- ZONE 200
- Part number
- D31865111
- Control number
- F3LA202006050028
EPSU AT FIN 11WL FAULTS DURING TEST ON HEAVY CHECK. REMOVED LT OVERWING SLIDE, FOUND LOOSE CONNECTOR, TIGHTENED CONNECTOR. REINSTALLED SLIDE ON ITEM 2 OF THIS LOG PAGE AND PERFORMED OPS TEST PER AMM 33-51-15-400-001-A, NO FAULTS FOUND.