Free report · Generated Nov 28, 2026 · tailcheck.me/intel/N347FR/sdrs

Service Difficulty Reports · N347FR

N347FR · 2019 AIRBUS A320-251N · Serial 8811

Service Difficulty Reports filed for N347FR, with the text of each report as the FAA holds it.

8 SDRs

  1. POWER SUPPLY

    Difficulty date
    Submitted
    JASC
    3350 · Lights
    Condition
    NO TEST
    Location
    ZONE 200
    Part number
    321431
    Control number
    F3LA202508260287

    AIRCRAFT WAS UNDERGOING HEAVY SERVICE CHECK DURING RON MAINTENANCE, ITEM #3 BATT/EPSU (11WL) EMER L FAULT. R&R EPSU BATTERY 11WL REF AMM 33-51-38-400-001-A/AMM 33-51-38-400-001 TEST OK.

  2. CLAMP

    Difficulty date
    Submitted
    JASC
    3610 · Pneumatic
    Condition
    LOOSE
    Location
    ZONE 400
    Control number
    F3LA202503070197

    DISCREPANCY: ENG 1 FIRE ECAM AFTER LANDING. ENGINE 1 BOTTLE DISCHARGED. UPON INSPECTION OF THE #1 ENG, FOUND PYLON BLEED DUCT CLAMPS LOOSE. TORQUED PYLON DUCT CLAMPS IAW AMM 36-11-49-400-330-A. NO EVIDENCE OF A FIRE.

  3. BATTERY

    Difficulty date
    Submitted
    JASC
    3350 · Lights
    Condition
    FAILED
    Location
    ZONE 200
    Part number
    32146210
    Control number
    F3LA2024092300142

    REFERENCE LTPR NR 5001334222-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INCOMING CHECKS FOUND EPSU BATTERIES 10 WL INPO REPLACEMENT REQUIRED IAW AMM 33-51-38-000-002-A REV. 99. REPLACED EPSU BATTERY AND POWER SUPPLY 10WL IAW AMM 33-51-38-400-002-A REV. 99.

  4. BATTERY

    Difficulty date
    Submitted
    JASC
    3350 · Lights
    Condition
    FAILED
    Location
    ZONE 200
    Part number
    32146210
    Control number
    F3LA2024092300141

    REFERENCE LTPR NR 5001334233-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INCOMING CHECKS FOUND EPSU BATTERIES 11 WL INPO REPLACEMENT REQUIRED IAW AMM 33-51-38-000-002-A REV/99. REPLACED EPSU BATTERY AND POWER SUPPLY 11WL IAW AMM 33-51-38-400-002-A REV. 99.

  5. BATTERY

    Difficulty date
    Submitted
    JASC
    3350 · Lights
    Condition
    FAILED
    Location
    ZONE 200
    Part number
    321431
    Control number
    F3LA2024092300143

    REFERENCE LTPR NR 5001334236-0010 AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. DURING INCOMING CHECKS FOUND EPSU BATTERY 13 WL INOP. REPLACEMENT REQUIRED IAW AMM 33-51-38-000-002-A REV.99. REPLACED EPSU BATTERY 13WL IAW AMM 33-51-38-400-002 REV. 99.

  6. DOOR SEAL

    Difficulty date
    Submitted
    JASC
    5310 · Fuselage
    Condition
    CORRODED
    Location
    ZONE 200
    Part number
    D5348004320600
    Control number
    F3LA2024091800132

    REFERENCE NR#5001334171-0010. AIRCRAFT WAS NOT GROUNDED AND IS IN CHECK FOR SCHEDULED MX. RH AFT DOOR SILL BEAM NUT PLATE HOLE AT FR68 IS CORRODED. REPAIR REQUIRED AFTER EVALUATION AS PER A320 NEO SRM 53-41-14-283-002 REV.41. REPAIRED BY INSTALLATION OF REPAIR ANGLE AND FILLER ON RH AFT PAX DOOR SILL AT FR68 AS PER A320 NEO SRM 53-41-14-300-001 PRINCIPLE 5 REV.41.

  7. TUBE

    Difficulty date
    Submitted
    JASC
    2910 · Hydraulic Power
    Condition
    DAMAGED
    Part number
    D2902083800000
    Control number
    F3LA2022040800024

    DISCREPANCY: LP188829-2, HYD G RSVR LO LVL. CORRECTIVE ACTION: SERVICED HYD G RSVR IAW AMM 12-12-29-611-001-A, ADDITIONAL CORRECTIVE ACTION FROM LP188830-2: #1 ENG HYD LEAK FOUND. CORRECTIVE ACTION: R/R PRESS ASSY IAW AMM 20-23-11-911-001-A./END/

  8. CONNECTOR

    Difficulty date
    Submitted
    JASC
    3397 · Lights
    Condition
    LOOSE
    Location
    ZONE 200
    Part number
    D31865111
    Control number
    F3LA202006050028

    EPSU AT FIN 11WL FAULTS DURING TEST ON HEAVY CHECK. REMOVED LT OVERWING SLIDE, FOUND LOOSE CONNECTOR, TIGHTENED CONNECTOR. REINSTALLED SLIDE ON ITEM 2 OF THIS LOG PAGE AND PERFORMED OPS TEST PER AMM 33-51-15-400-001-A, NO FAULTS FOUND.

Sources

FAA Service Difficulty Reports