N623NK: 2013 AIRBUS A320-232

Public aircraft records for N623NK, from the FAA, the NTSB, Transport Canada and the FAA Service Difficulty Reporting System, mirrored by Tailcheck. Each section names its source; the sync dates are listed at the end. Page built 2026-11-29. Recent flight activity appears on this page in the browser and is not part of this public summary.

Registration

StatusValid
ManufacturerAIRBUS
ModelA320-232
Serial number5861
Year of manufacture2013
Aircraft typeFixed Wing Multi-Engine
EngineIAE V2527-A5
Engine typeTurbo-fan
Airworthiness classStandard
Airworthiness categoryTransport
Airworthiness date11/25/2013
Certificate issued07/01/2016
Certificate expires07/31/2029
Registration typeCorporation
RegistrantWILMINGTON TRUST CO TRUSTEE
Mode S code (hex)A82298
Part 135 aircraft listNot found in the FAA Part 135 list released Nov 16, 2026. The list names aircraft on a charter certificate in that release; it does not show past or other use.

Registered to the same corporation since at least Jul 1, 2016, 10 years 4 months.

Ownership: the current certificate's issue date, and the FAA's index of documents it has received. That index is partial and starts in March 2026, so a sale may not appear here. Earlier owners and the dates of earlier sales are not in our data; they are in the FAA aircraft records file. Part 135: according to the FAA Part 135 Operators and Aircraft list released Nov 16, 2026. The FAA has corrected this list before and it can contain errors. Not being listed does not mean the aircraft was never flown for hire.

Source: FAA Civil Aviation Registry, FAA registry record for N623NK.

N-number history

No cancelled registration is on file for this mark in the FAA deregistered-aircraft file. That file reaches back decades, not to the beginning of the registry.

Safety history

NTSB accidents (0)

No NTSB case matches this airframe under this registration or, where the serial number is known, by serial number. No match is not proof that no accident occurred.

FAA incidents, AIDS (0)

No FAA Accident and Incident Data System record for this airframe.

Transport Canada CADORS (0)

No Canadian occurrence report names this airframe.

Service Difficulty Reports

View all Service Difficulty Reports

38 reports filed against this airframe; the most recent:

  • 2026-04-23 Air Conditioning: MEGAPHONE A3061402; Control number GTIA2026042739359. FA REPORTS FUMES SMELL AFT CABIN AFTER TAKE OFF-PER TSM 05-50-00-810-831-A DECISION TABLE TYPE 7 CORRECTIVE ACTION. PERFORMED GVI OF APU AND HYD COMPONENTS NO DEFECTS NOTED. LEVEL A DECONTAMINATION PE…
  • 2026-04-14 Air Conditioning: A/C PACK; Control number GTIA2026041639354. DURNING CRUISE @ 380,FA`S IN REAR OF AIRCRAFT SAID THEY SMELLED "DIRTY SOCK"FUMES. PUT PACK 2 OFF AND CLOSED XBLEED,FA`S REPORTED NO CHANGE PACK 2 ON,THEN PACK 1 OFF. FA`S REPOERTED FUMES WERE BETTER…
  • 2026-01-06 Air Conditioning: UNKNOWN; Control number GTIA2026010839241. SMELLED ODOR ON TAKE OFF AND LANDING -FOUND EVIDENCE OF HYDRAULIC FLUID LEAKING FROM YELLOW SYSTEM HP MANIFOLD BAY INTO APU AIR INLET. REPLACED PACKINGS ON YELLOW SYSTEM HP MANIFOLD IAW AMM 29-13-14. …
  • 2025-09-25 Stabilizers: BUSHING 552800200200; Control number GTIA2025092939101. AFTER BUSHINGS REMOVAL CORROSION WAS FOUND ON INNER BORE HINGE FITTING Ñ3 AT RH ELEVATOR (2EA) RAF 3589623-01 CREATED-REPAIRED BOTH BORES AND REPLACED BUSHINGS (2 EA) ON HINGE FITTING #3 AT RH ELEVAT…
  • 2025-09-25 Stabilizers: BUSHING 5528000200300; Control number GTIA2025092939100. AFTER BUSHINGS REMOVAL CORROSION WAS FOUND ON INNER BORE HINGE FITTING Ñ4 OB LUG AT RH ELEVATOR (1 EA) RAF 3589622-02 CREATED -REPAIRED BOTH BORES AND REPLACED BUSHING (1 E/A) ON HINGE FITTING #4 OUT…
  • 2025-09-25 Stabilizers: BUSHING 5528000200300; Control number GTIA2025092939099. AFTER BUSHINGS REMOVAL CORROSION WAS FOUND ON INNER BORE HINGE FITTING Ñ6 AT RH ELEVATOR (2EA). RAF 3589622-01 CREATED-REPAIRED BOTH BORES AND REPLACED BUSHINGS (2 E/A) ON HINGE FITTING #6 AT RH ELEV…
  • 2025-09-25 Stabilizers: BUSHING 5528000200300; Control number GTIA2025092939098. AFTER BUSHING REMOVAL CORROSION WAS FOUND ON INNER BORE HINGE FITTING #1, 2, AND 3 AT LH ELEVATOR RAF 3589621-02 CREATED SEE APPENDIX 3589621-02-REPAIRED BOTH BORES AND REPLACED BUSHINGS (2 EA) ON HIN…
  • 2025-09-25 Fuselage: SKIN PANEL D5348008225400; Control number GTIA2025092939097. CRACK INDICATION FOUND IN FASTENER HOLE (LOWER INBOARD POSITION) LOCATED AT FR 68 DOOR STOP FITTING 1 RH SIDE. RAF 3589624-01 GENERATED -PERFORMED REPAIR ON FASTENER HOLE (LOWER INBOARD POSITION) LOCA…
  • 2025-09-25 Fuselage: SKIN PANEL D5348008225400; Control number GTIA2025092939096. CRACK INDICATION FOUND IN FASTENER HOLE ( LOWER INBOARD POSTION) LOCATED AT FR 68 DOOR STOP FITTING 6 LT SIDE. RAF 3589623-02 GENERATED -PERFORMED REPAIR ON FASTENER HOLE (LOWER INBOARD POSITION) LOCA…
  • 2025-08-11 Equipment/Furnishings: FLASHLIGHT; Control number GTIA2025081439044. FLIGHT ATTENDANT POSITION L2 FLASHLIGHT INOP-R/R L2 FLASHLIGHT IAW AMM 25-63-00. OPERATIONAL CHECK OK. A/C OK FOR SVC.
  • 2025-01-13 Equipment/Furnishings: MEGAPHONE A3061402; Control number GTIA2025011338667. FWD MEGAPHONE INOP-R+R MEGAPHONE IAW AMM 25-65-01. MOC 77744 NOTIFIED
  • 2024-06-22 Air Conditioning: A/C PACK UNKNOWN; Control number GTIA2024062438193. FUME EVENT ON DECENT (PACK 1)-PERFORMED TSM 05-50-00-810-831-A. IDENTIFIED SOURCE OF ODOR TO BE PACK 1. SEE LP 3445741-2 FOR CORRECTIVE ACTION.
  • 2024-06-20 Air Conditioning: UNKNOWN; Control number GTIA2024062038189. FA SMELLED STRONG EXSAUST IF THE AFT GALLEY DURING DECENT / LANDING-PERFROMED TSM 05-50-00-810-831-A NO DEFECTS NOTED AT THIS TIME AFT GALLEY SMELLED OF CIGARETTES A/C OK FOR SERVICE MOC 109580
  • 2024-05-27 Air Conditioning: A/C PACK UNKNOWN; Control number GTIA2024052838147. DIRTY SOCK SMELL MID-CABIN AFT GOING THROUGH 5000 ON LANDING FUMES QRH APPLIED PACK 2 OFF, X BLEED SHUT-SMEL PERSISTED -PREFORMED IDENTIFICATION OF CABIN ODOR IAW TSM 05-50-00-810-831-A FOUND PACK 2 T…
  • 2024-05-27 Air Conditioning: UNKNOWN; Control number GTIA2024052838146. FA'S STATED THAT WHEN THE GEAR CAME DOWN AT 2000FT THEY SMELLED A WET SOCK SMELL-PERFORMED FUME EVENT FAULT ISOLATION PROCEDURES IAW TSM 05-50-810-831. PERFORMED ENGINE RUNS OF ENG #1 & ENG #2 IAW AMM…
  • 2024-03-25 Air Conditioning: UNKNOWN; Control number GTIA2024032638023. FUME EVENT DIRTY SOCK SMELL FRONT OF AIRCRAFT SLOWING TO APPROACH SPEED. TURNED PACK 1 OFF SMELL DISAPATED ( PACKS - A320 WITH MOD. 30626/MP K6443 (ENHANCED ECS) OR A321 WITH MOD. 157080/MP K17996 (PA…
  • 2024-03-24 Air Conditioning: A/C PACK UNKNOWN; Control number GTIA2024032638020. "DIRTY SOCK" SMELL FUME EVENT JUST PRIOR TO LANDING- 8000FT. 210 KTS, LOW THRUST. TURNING PACK 1 OFF IMMEDIATELY CLEARED THE ODOR.-PERFORMED TSM 21-00-00-810-802-A AND TSM 05-50-00-810-831. PERFORMED …
  • 2024-02-04 Air Conditioning: A/C PACK UNKNOWN; Control number GTIA2024020637835. SMELL OF CAT URINE IN COCKPIT AND CABIN DID FUME ELIMINATION QRH AND PACK 1+2 FAULT-PERFORMED PACK BURN IAW AMM 21-00-00 PACK 1 GOOD NO SMELL NOTED. PACK 2 FAULTED DURING TEST AND TRANSFERED TO LOG PA…
  • 2024-01-10 Air Conditioning: UNKNOWN UNKNOWN; Control number GTIA2024011037762. FUME /DIRTY SOCKS SMELL DURING DESCENT THROUGH 10-12,000FT.-PERFORMED LEVEL B REMOVAL OF THE CONTAMINATION OF THE ECS (PACK 2) IAW AMM 21-00-00-615-803-A OPS CHK GOOD NO SCENT NOTED A/C OKAY FOR SVC
  • 2024-01-03 Air Conditioning: UNKNOWN UNKNOWN; Control number GTIA2024010737732. FUME EVENT DESCENDING 7,000 SMELL VINEGAR-PER TSM 05-50-00-810-831 RAN BOTH PACKS ON APU BLEED NO SIGN OF CONTAMINATION.RAN BOTH ENG BLEED FOUND NO CONTAMINATION FROM ENG#2 PACKS 2 BUT HAD ODOR FROM E…
  • 2023-12-02 Equipment/Furnishings: FLASHLIGHT UNKNOWN; Control number GTIA2023120537674. FWD LH FA JUMPSEAT FLASHLIGHT INOP. ( FLASHLIGHT AND HOLDERS (FLIGHT DECK OR CABIN) )-R/R FLASHLIGHT ASSY. IAW AMM 25-6-000. OPS CHECK GOOD. THIS CLEARS DMI#3291772-1. MOC NOTIFIED. PLACARD REMOVED. D…
  • 2023-06-26 Air Conditioning: UNKNOWN UNKNOWN; Control number GTIA2023062637291. AROUNF 5000 FT ON DOWNWIND SMELLY SOCK SMELL FAR ABOUT 2 MINS COCKPIT-OPS TEST IAW 36-11-00 NO SMELLS NOTED AT THIS TIME. ACFT OK FOR CONT SRVC
  • 2022-10-09 Equipment/Furnishings: MEGAPHONE A3061402; Control number GTIA2022101036716. MEGAPHONE INOP-R + R MEGAPHONE IAW AMM 25-63-00. OPS CHECK GOOD
  • 2022-10-04 Stabilizers: NONE D5537131320200; Control number GTIA2022100636704. RUDDER HINGE FITTING #3 REQUIRE REPLACEMENT DUE TO ELONGATED BUSHINGS IN PREVIOUS REPAIRS. RAF-01 2907255-01-ACCOMLPISHED VERTICLE STAB ATTACH FITTING HINGE ARM BR 3 REPLACEMENT IN ACCORDANCE WITH EA…
  • 2022-10-04 Stabilizers: NONE D5537131800000D5; Control number GTIA2022100636703. RUDDER HINGE ARM BEARING #4 HAS ELONGATED HOLE IN EXISTINE REPAIR. RAF-01 2907254-02 GENERATED-ACCOMPLISHED VERTICAL STAB ATTACHMENT FITTINGS HINGE ARM BR4 EXISTING BUSHING REPAIRS AND ENLONGATED HOL…

Not this airframe: 1 report filed under this N-number for a different aircraft.

Fleet pattern, A320

  • Fuselage: FLOOR SUPPORT, 2360 reports
  • Fuselage: FLOORBEAM, 2137 reports
  • Air Conditioning: UNKNOWN, 1996 reports
  • Fuselage: FLOOR PANEL, 1962 reports
  • Fuselage: SEAT TRACK, 1733 reports
  • Lights: POWER SUPPLY, 1622 reports
  • Lights: BATTERY, 1455 reports
  • Lights: LIGHT, 1152 reports
  • Fuselage: STRINGER, 1068 reports
  • Fuselage: SKIN, 1054 reports

Type documents

View all STCs

View all SAIBs

Type certificate data sheetA28NM · Revision 55
Revised · Aug 13, 2026
STCs approved for this model277
  • ST09939AC: Installation of the Spacex Starlink Aviation Satcom System (Space Exploration Technologies Corp./Starlink Aviation)
  • ST09829DS: Cabin interiors reconfiguration on Airbus A320 fleet (United Airlines)
  • ST03438NY: Installation of Adams Rite Lavatory Equipment (Delta Engineering Corporation)
  • ST12434AC: Replacement of the wing fuel tank access panel gasket (Aviation Devices & Electronic Components, LLC)
  • ST02714CH: Modify the aircraft interior to match standard passenger configurations (Atin OOH LLC)
Special Airworthiness Information Bulletins (SAIBs) for this model4

Source: FAA Dynamic Regulatory System, as of Nov 23, 2026. Matched on maker and model. An STC listed here can be installed on this model; whether one is installed on this aircraft is recorded in its logbooks and Form 337s. An SAIB is information, not a requirement.

Airworthiness Directives

View all Airworthiness Directives

523 Airworthiness Directives published for the A320-232; current ADs first. Applicability depends on the serial number and the installed engine, propeller and equipment, and compliance is recorded in the maintenance logbooks, not here.

463 more in the free report.

Proposed ADs that may apply · not in force (5)

FAA proposals that name this maker and model. A proposed AD has no legal effect; it may change or be withdrawn before the FAA issues a final rule.

This list can be incomplete, and a proposal shown here may not apply to this aircraft. We matched 136 of the 152 open proposals to models, some of them from the proposal's text only; 16 could not be matched and are not checked here. A proposal can also cover only some serial numbers. Read the docket before relying on it.

What these records do not prove

  • No matching record is not proof that no accident, incident or defect occurred; events abroad, unreported events and repairs done without a filing leave no trace here.
  • An N-number is a registration mark, not an airframe; compare serial numbers before attributing a prior aircraft's record to this one.
  • An AD list for the type is not AD compliance; applicability and compliance are settled in the maintenance logbooks.
  • A current registration is not a title search; liens and the chain of ownership live in the FAA aircraft records file.

Read more: what a free aircraft history report shows · how to check accident history by N-number · N-number history and reuse.

Sources and freshness

  • FAA Civil Aviation Registry: last synced 2026-11-23
  • NTSB accidents and incidents: last synced 2026-11-29
  • FAA Accident and Incident Data System: last synced 2026-11-23
  • Transport Canada CADORS: last synced 2026-11-23
  • FAA Service Difficulty Reports: last synced 2026-11-23
  • FAA DRS Airworthiness Directives: last synced 2026-11-23
  • Federal Register AD feed: last synced 2026-11-23
  • FAA DRS Type Certificate Data Sheets: last synced 2026-11-23
  • FAA DRS Special Airworthiness Information Bulletins: last synced 2026-11-23
  • FAA DRS Supplemental Type Certificates: last synced 2026-11-23
  • FAA DRS proposed Airworthiness Directives: last synced 2026-11-23
  • FAA Part 135 Operators and Aircraft list: last synced 2026-11-23