Free report · Generated Nov 28, 2026 · tailcheck.me/intel/N68310/sdrs
Service Difficulty Reports · N68310
N68310 · 1979 CESSNA 310R · Serial 310R1614
Service Difficulty Reports filed for N68310, with the text of each report as the FAA holds it.
2 SDRs
REGULATOR
- Difficulty date
- Submitted
- JASC
- 2422 · Electrical Power
- Condition
- MALFUNCTIONED
- Location
- LT ALTERNATOR
- Part number
- 99101263
- Control number
- 2018FA0000087
DETERMINED THE LEFT ALTERNATOR WAS OVERCHARGING THE SYSTEM RESULTING IN TRIPPING OF THE OVERVOLTAGE RELAY, DRAINING OF THE AIRCRAFT BATTERY, AND LOSS OF ELECTRICAL POWER. POSSIBLE CONTRIBUTING FACTORS TO THE LOSS OF POWER, SUNLIGHT ON THE INSTALLED LOW VOLTAGE WARNING LIGHT AT THE TIME OF FAILURE MADE READING THE LIGHT DIFFICULT OR IMPOSSIBLE. THE ALTERNATOR FAILURE LIGHTS AND AMMETER ARE HIDDEN BEHIND THE POWER LEVERS DURING FLIGHT.
ELECTRICAL SYS
- Difficulty date
- Submitted
- JASC
- 2400 · Electrical Power
- Condition
- FAILED
- Control number
- 7ILA2018F00000
AIRCRAFT EXPERIENCED ELECTRICAL SYSTEM FAILURE RESULTING IN PILOT PERFORMING EMERGENCY LANDING.