Free report · Generated Nov 29, 2026 · tailcheck.me/intel/N8564S/sdrs
Service Difficulty Reports · N8564S
Service Difficulty Reports filed for N8564S, with the text of each report as the FAA holds it.
1 SDR
BOLT
- Difficulty date
- Submitted
- JASC
- 3210 · Landing Gear
- Condition
- BROKEN
- Location
- MLG
- Part number
- NAS150DH52
- Control number
- 2SEG2014FA0000408
DURING A TAKEOFF ROLL, PILOT HEARD A POP AND THE ACFT PULLED HARD TO THE LT AND LEFT THE RUNWAY AND ENDED UPSIDE DOWN. THE LEFT MLG FORWARDED ATTACH BOLT BROKE AND ALLOWED THE LT MLG TO COME LOOSE AND CAUSED THE LEFT "PULL" OF THE ACFT. THIS BOLT ACCORDING TO THE ACFT RECORDS HAD 1553 HOURS TIME IN SERVICE. THE MFG RECOMMENDS A REPLACEMENT OF 600- 1000 HOURS TIME IN SERVICE FOR THIS BOLT.