Free report · Generated Nov 29, 2026 · tailcheck.me/intel/N960JS/sdrs
Service Difficulty Reports · N960JS
N960JS · 2004 GULFSTREAM AEROSPACE G-IV (G400) · Serial 1521
Service Difficulty Reports filed for N960JS, with the text of each report as the FAA holds it.
3 SDRs
SENSOR
- Difficulty date
- Submitted
- JASC
- 3242 · Landing Gear
- Condition
- DIRTY
- Location
- ZONE 700 BRAKE
- Part number
- 6006508
- Control number
- AWKA2024100300756
IMMEDIATELY AFTER TAKEOFF, WE RECEIVED A âBRAKE OVHTâ CAS. WE LEFT THE GEAR DOWN, BRAKES COOLED TO <200, THEN RETRACTED THE GEAR PER THE QRH. IN FLIGHT, âBRAKE OVHTâ CAS CAME ON AGAIN. FOLLOWED QRH CHECKLIST, LOWERED GEAR, BRAKE TEMP INDICATIONS ON L/H OUTBOARD BRAKE THEN WENT TO >999*. AN EMERGENCY WAS DECLARED FOR LANDING BY THE CREW. FROM MAINTENANCE: FOUND A DIRTY CONNECTOR, REMOVED AND CLEANED CONNECTOR, OPS CHECK GOOD, NO OTHER DEFECTS NOTED REFERENCE G400 AMM 32-00-00.
WARNING MESSAGE
- Difficulty date
- Submitted
- JASC
- 3150 · Instruments
- Condition
- FALSE ACTIVATION
- Location
- NR 1 FGC
- Control number
- W6JA20230116051
AIRCRAFT ENROUTE FROM KVNY TO MMMY. WHEN A FGC #1 FAIL AMBER CAS MESSAGE APPEARED. CREW DECLARED AN EMERGENCY AND DIVERTED TO SDL AND LANDED WITHOUT FURTHER PROBLEM. THE CREW CONTACTED MX CONTROL AND DEFERRED FGC#1 PER MEL 22-1. AIRCRAFT RETURNED TO KVNY FOR NECESSARY REPAIRS. PERFORMED ASCB BUSS CHECK, WITH NO DISCREPANCIES. SWAPPED FGC #1 & 2, & PERFORMED AFGSC SYSTEM OPERATIONAL CHECK WITH NO DISCREPANCIES NOTED. ALL WORK ACCOMPLISHED IAW AMM 22-01-00. FGC'S REMAIN SWAPPED FOR TROUBLESHOOTING WITH NO FURTHER ISSUES AT THIS TIME.
ACTUATOR
- Difficulty date
- Submitted
- JASC
- 7830 · Engine Exhaust
- Condition
- LEAKING
- Location
- THRUST REVERSER
- Part number
- 1159SCP40211
- Control number
- W6JA20190510031
AT CRUISE FLIGHT, FLIGHT CREW RECEIVED AMBER CHECK âHYD QUANTITYâ WARNING. MONITORED HYDRAULIC FLUID LEVEL AND DECLARED AN EMERGENCY LANDING IN OMA, DUE TO LEVEL CONTINUING TO DROP. IDENTIFIED LEAK ON RIGHT THRUST REVERSER ACTUATOR. SERVICED HYDRAULIC RESERVOIRS AND PREPARED AIRCRAFT FOR FERRY FLIGHT TO LNK FOR MAINTENANCE. RT TR ACTUATOR REPLACED WITH OVERHAULED UNIT P/N 1159SCP402-11, COMPLIED WITH OPERATIONAL AND LEAK CHECKS, REFERENCE AMM 78-00-00.